Abstract:
Background Sagittal split ramus osteotomy (SSRO) can be associated with
postoperative neurosensory disturbances. This study aimed to evaluate the
effectiveness of computer-assisted SSRO in reducing the incidence and severity
of neurosensory alterations, using a surgical guide fabricated by computeraided
design and rapid prototyping (to guide bone cutting lateral to the
inferior alveolar nerve).
Methods A prospective double-blind, randomized controlled, clinical trial of
computer-assisted SSRO vs conventional SSRO (assigned in a split-mouth
design) in eight patients, mean age 23 (range 18–30) years, who participated
in one session preoperatively and three sessions at 1 week and 1, 3 and
6 months postoperatively. At each session, subjective oral sensation was scored
and quantitative sensory tests were performed. Neurosensory changes were
compared between the two sides.
Results The results showed that on the computer-assisted SSRO sides,
patients had lower postoperative abnormal thresholds for the Semmes–Weinstein
monofilaments on lower lip and chin (p < 0.05 at 3 months) and for the
two-point discrimination on lower lip (p < 0.05 at 1 week) and chin (p < 0.05
at 6 months), with fewer abnormal self-reported changes in lower lip sensation
(p < 0.05 at 1 week) after surgery.
Conclusions These findings imply that computer-assisted SSRO is associated
with better levels of neurosensory function after surgery. Copyright © 2013
John Wiley & Sons, Ltd.